summaryrefslogtreecommitdiff
path: root/nuttx/configs/vsn/src/README.txt
diff options
context:
space:
mode:
Diffstat (limited to 'nuttx/configs/vsn/src/README.txt')
-rw-r--r--nuttx/configs/vsn/src/README.txt22
1 files changed, 11 insertions, 11 deletions
diff --git a/nuttx/configs/vsn/src/README.txt b/nuttx/configs/vsn/src/README.txt
index 732ede5e6..3760d55b3 100644
--- a/nuttx/configs/vsn/src/README.txt
+++ b/nuttx/configs/vsn/src/README.txt
@@ -3,14 +3,14 @@ VSN Board Support Package, for the NuttX, Uros Platise <uros.platise@isotel.eu>
===============================================================================
http://www.netClamps.com
-The directory contains start-up and board level functions.
+The directory contains start-up and board level functions.
Execution starts in the following order:
- sysclock, immediately after reset stm32_rcc calls external
clock configuration when
CONFIG_ARCH_BOARD_STM32_CUSTOM_CLOCKCONFIG=y
is set. It must be set for the VSN board.
-
+
- boot, performs initial chip and board initialization
- sched/os_bringup.c then calls user entry defined in the .config file.
@@ -20,39 +20,39 @@ Naming throughout the code
- _init(): used to be called once only, after powerup, to perform board
initialization
- - _start() or called via FS _open(): starts peripheral power, puts it
+ - _start() or called via FS _open(): starts peripheral power, puts it
into operation
- _stop() or called via FS _close(): opposite to _start()
-
+
System notifications (a sort of run-levels)
===========================================
On the VSN, NSH represents the core application as it supports scripts
-easily adaptable for any custom application configuration. NSH is
+easily adaptable for any custom application configuration. NSH is
invoked as follows (argument runs a script from the /etc/init.d directory):
- nsh init: on system powerup called by the NuttX APP_START
-TODOs:
-
+TODOs:
+
- nsh xpowerup: run on external power used to:
- try to setup an USB serial connection
- configure SLIP mode, internet
- start other internet services, such as telnetd, ftpd, httpd
-
+
- nsh xpowerdown: run whenever USB recevied suspend signal or
external power has been removed.
- used to stop internet services
-
+
- nsh batdown: whenever battery is completely discharged
-
+
Compile notes
===============================
To link-in the sif_main() utility do, in this folder:
- make context TOPDIR=<path to nuttx top dir>
-
+
This will result in registering the application into the builtin application
registry.