+# For a description of the syntax of this configuration file,
+# see misc/tools/kconfig-language.txt.
+#
+
+comment "FreeModbus"
+
+config MB_ASCII_ENABLED
+ bool "Modbus ASCII support"
+ depends on MODBUS
+ default y
+
+config MB_RTU_ENABLED
+ bool "Modbus RTU support"
+ depends on MODBUS
+ default y
+
+config MB_TCP_ENABLED
+ bool "Modbus TCP support"
+ depends on MODBUS
+ default y
+
+config MB_ASCII_TIMEOUT_SEC
+ int "Character timeout"
+ depends on MB_ASCII_ENABLED
+ default 1
+ ---help---
+ Character timeout value for Modbus ASCII
+
+ The character timeout value is not fixed for Modbus ASCII and is therefore
+ a configuration option. It should be set to the maximum expected delay
+ time of the network.
+
+config MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS
+ int "Timeout to wait before sending"
+ depends on MB_ASCII_ENABLED
+ default 0
+ ---help---
+ Timeout to wait in ASCII prior to enabling transmitter
+
+ If defined the function calls vMBPortSerialDelay with the argument
+ MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS to allow for a delay before
+ the serial transmitter is enabled. This is required because some
+ targets are so fast that there is no time between receiving and
+ transmitting the frame. If the master is to slow with enabling its
+ receiver then he will not receive the response correctly.
+
+config MB_FUNC_HANDLERS_MAX
+ int "Maximum number of Modbus functions"
+ depends on MODBUS
+ default 16
+ ---help---
+ Maximum number of Modbus functions codes the protocol stack should support.
+
+ The maximum number of supported Modbus functions must be greater than
+ the sum of all enabled functions in this file and custom function
+ handlers. If set to small adding more functions will fail.
+
+config MB_FUNC_OTHER_REP_SLAVEID_BUF
+ int "Size of Slave ID report buffer"
+ depends on MB_FUNC_OTHER_REP_SLAVEID_ENABLED
+ default 32
+ ---help---
+ Number of bytes which should be allocated for the Report Slave ID command.
+
+ This number limits the maximum size of the additional segment in the
+ report slave id function. See eMBSetSlaveID() for more information on
+ how to set this value. It is only used if MB_FUNC_OTHER_REP_SLAVEID_ENABLED
+ is set to 1.
+
+config MB_FUNC_OTHER_REP_SLAVEID_ENABLED
+ bool "Report Slave ID function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Report Slave ID function should be enabled.
+
+config MB_FUNC_READ_INPUT_ENABLED
+ bool "Read Input Registers function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Read Input Registers function should be enabled.
+
+config MB_FUNC_READ_HOLDING_ENABLED
+ bool "Read Holding Registers function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Read Holding Registers function should be enabled.
+
+config MB_FUNC_WRITE_HOLDING_ENABLED
+ bool "Write Single Register function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Write Single Register function should be enabled.
+
+config MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED
+ bool "Write Multiple registers function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Write Multiple registers function should be enabled.
+
+config MB_FUNC_READ_COILS_ENABLED
+ bool "Read Coils function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Read Coils function should be enabled.
+
+config MB_FUNC_WRITE_COIL_ENABLED
+ bool "Write Coils function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Write Coils function should be enabled.
+
+config MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED
+ bool "Write Multiple Coils function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Write Multiple Coils function should be enabled.
+
+config MB_FUNC_READ_DISCRETE_INPUTS_ENABLED
+ bool "Read Discrete Inputs function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Read Discrete Inputs function should be enabled.
+
+config MB_FUNC_READWRITE_HOLDING_ENABLED
+ bool "Read/Write Multiple Registers function"
+ depends on MODBUS
+ default y
+ ---help---
+ If the Read/Write Multiple Registers function should be enabled.